Pressure reducer electric valve

Purpose:

opening and closing of the high-pressure gas line, reduction of high pressure into low pressure and maintenance of low pressure within specified limits

Performances:
Operating medium consumption, mg/s
0.036 – 9
Inlet operating pressure (excessive), Pa (kg/cm2)
343•105 (350) – 19.6•105 (20)
Outlet operating pressure (excessive), Pa (kg/cm2)
(4.41)•105 (4.5)
Operating temperature range, °C
-40 – 50
Direct current power supply voltage, V
27
Lifetime, years
10.5
Mass, kg
1.9